Transformer Maintenance
DC-5000V Transformer Evacuation System
The DC-5000V transformer evacuation system is designed to generate a high and stable vacuum required for effective evacuation of transformer tanks. The system is applied during installation, servicing, and operation of oil-filled electrical equipment, including power transformers and high-voltage switchgear, with voltage ratings up to 1,150 kV. The DC-5000V transformer evacuation system is suitable for vacuum drying of transformer insulation. It is intended for use by installation, repair, and maintenance companies specializing in transformer servicing and transformer oil treatment.
Description
The DC-5000V transformer evacuation system is designed to generate a high and stable vacuum required for effective evacuation of transformer tanks. The system is applied during installation, servicing, and operation of oil-filled electrical equipment, including power transformers and high-voltage switchgear, with voltage ratings up to 1,150 kV.
The DC-5000V transformer evacuation system is suitable for vacuum drying of transformer insulation. It is intended for use by installation, repair, and maintenance companies specializing in transformer servicing and transformer oil treatment.
Specification
| No. | Parameter | Value |
| 1 | Geometric pumping speed, gpm (m3/h) | 22,000 (5,000) |
| 2 | Operating vacuum, psi (mbar) | <0.014 (<1) |
| 3 | Cooling method | Air |
| 4 | Maximum power consumption, kW | 32 |
| 5 | Connection, inlet/outlet | Dn200/Dn65 |
| 6 | Dimensions, mm, max: | |
| 7 | — length, in (mm) | 92.5 (2,350) |
| 8 | — width, in (mm) | 56.7 (1,440) |
| 9 | — height with/without eyebolts, in (mm) | 65/59.8 (1,650/1,520) |
| 10 | Weight, lbs (kg), max | 4,850 (2,200) |
Benefits
Key Benefits of the DC-5000V
- Fast Gas Removal: rapid extraction of air, vapor, non-aggressive gases, and vapor-gas mixtures facilitated by an integrated booster.
- Wide Equipment Compatibility: suitable for servicing and operation of oil-filled transformers and high-voltage switches up to 1,150 kV.
- High Vacuum Performance: ensures deep and efficient evacuation of transformer tanks.
Details
1
Description
The DC-5000V transformer evacuation system is designed to generate a high and stable vacuum required for effective evacuation of transformer tanks. The system is applied during installation, servicing, and operation of oil-filled electrical equipment, including power transformers and high-voltage switchgear, with voltage ratings up to 1,150 kV.
The DC-5000V transformer evacuation system is suitable for vacuum drying of transformer insulation. It is intended for use by installation, repair, and maintenance companies specializing in transformer servicing and transformer oil treatment.
2
Specification
| No. | Parameter | Value |
| 1 | Geometric pumping speed, gpm (m3/h) | 22,000 (5,000) |
| 2 | Operating vacuum, psi (mbar) | <0.014 (<1) |
| 3 | Cooling method | Air |
| 4 | Maximum power consumption, kW | 32 |
| 5 | Connection, inlet/outlet | Dn200/Dn65 |
| 6 | Dimensions, mm, max: | |
| 7 | — length, in (mm) | 92.5 (2,350) |
| 8 | — width, in (mm) | 56.7 (1,440) |
| 9 | — height with/without eyebolts, in (mm) | 65/59.8 (1,650/1,520) |
| 10 | Weight, lbs (kg), max | 4,850 (2,200) |
3
Benefits
Key Benefits of the DC-5000V
- Fast Gas Removal: rapid extraction of air, vapor, non-aggressive gases, and vapor-gas mixtures facilitated by an integrated booster.
- Wide Equipment Compatibility: suitable for servicing and operation of oil-filled transformers and high-voltage switches up to 1,150 kV.
- High Vacuum Performance: ensures deep and efficient evacuation of transformer tanks.